Brand Name : Readeagle
Model Number : Aries 2200
Certification : CE&ISO
Place of Origin : Beijing
MOQ : 1set
Price : US$5888-7888/Set
Payment Terms : L/C, T/T, Western Union
Supply Ability : 10sets/1week
Delivery Time : 5-8 work days
Packaging Details : Carton pallet or Synthetic case
Type : Anesthesia Equipment
Instrument classification : Class III
Application : Applied for child and adult
Display : 10.4"TFT screen
Warranty : 1 Year
Ventilation mode : IPPV,SIMV,Sign,Manual,Standy
Hospital Medical Icu Anesthesia Machine ARIES 2200
Specifications | |
Respiration mode | IPPV, SIMV, SIGH, MANUAL, STANDBY, DEMO |
I:E ratio | 8:1~1:8 |
Tidal Volume | 50ml ~1600ml |
Respiratory frequency | 1~65bpm |
PEEP | mechanical |
Waveform | P-t, F-t |
Patient type | Adult, pediatric |
Display | 10.4 TFT color screen |
Driven mode | Pneumatically Driven. Electronically Controlled |
Pressure Setting | 1-60cmH2O |
Trigger Pressure | -20-20cmH2O |
Working Mode | Semi-open / Semi-closed / Closed system |
Gas Supply Pressure | O2: 0.27Mpa-0.55Mpa N2O: 0.27Mpa-0.55Mpa |
Inspiration Plateau | 0-55% Ti |
1) 10.4" TFT screen (Sharp brand), all parameters are clearly showed.
2) Metal frame, with plastic spray, durable and lasting.
3) Double vaporizer station, selectatec compatible.
4)Classical Flowmeter of 4 tubes, with O2/N2O linkage device.
5) Could be easily upgraded with functions: eg adding Multi-parameter Monitor, CO2 Monitor, AMIS System
6)Use advanced differential pressure sensor (Honeywell brand) to monitor tidal volume, the sensor probe is built inside the absorber, so as to avoid the affect of water vapor on tidal volume and improve the accuracy.
Safety Function
·When airway pressure reach 6kPa, APL valve will automatically
release gas.
·When airway pressure reach 6kPa, the Bellows will stop sending gas
to patient.
·Alarm parameters (Audible and/or visual signal):
1)Airway Pressure high / low limit
2)FiO2 high/low limit
3)Minute Ventilation Alarm
4)Low O2 Supply Pressure(when O2 Supply Pressure is lower than
0.15Mpa, will arouse Audible Alarm)
5)N2O automatic Cutoff Alarm
·Monitoring parameters (Under Manual and Ventilation):
Tidal Volume / Respiratory Frequency
Minute ventilation / Airway Pressure
Inspiration Plateau / Respiration mode / FiO2
Electrical Specification
·Mains: 100-240V, 50/60Hz
·Battery: 12V DC, minimum 120 min.(if with)
·Power consumption: ≤50W
Optional
·Patient Monitor
·York Device
·CO2 Monitor
·AGSS
·AMIS
·Circle absorber heating function
Name: Display
10.4" TFT screen (Sharp brand), all parameters are clearly showed
Name: Anaesthetic evaporator
Equipped with two high-precision evaporators, anesthetic drugs are
optional
Name: bellows
Patent bellows
Child and adult bellows are integrated into one.
Name: Breathing circuit
Double tank loop can absorb exhaust gas fully
![]() |
Multifunctional respiratory Anestesia machine professional suction Anaesthesia system Images |